NORITZ N-0751M-DVC INSTALLATION MANUAL Pdf Download (2024)

NORITZ N-0751M-DVC INSTALLATION MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. Noritz Manuals
  4. Water Heater
  5. N-0751M-DVC
  6. Installation manual

NORITZ N-0751M-DVC INSTALLATION MANUAL Pdf Download (2)

Tankless gas water heater

Hide thumbs Also See for N-0751M-DVC:

  • Installation manual (27 pages)
  • ,
  • Service manual (96 pages)
  • ,
  • Field manual (60 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
  • Contents
  • Table of Contents
  • Bookmarks

Table of Contents

  • Included Accessories

  • Optional Accessories

  • Quick Connect Multi System Installation

  • System Diagram

  • Before Installation

  • Choosing Installation Site

  • Installation Clearances

  • Installation

  • Securing to the Wall

  • Vent Pipe Installation

  • Water Piping

  • Water Treatment

  • Plumbing Applications

  • Electrical Wiring

  • Operation Panel

  • Pump Wiring

  • Connecting the Pump Control Wire

  • Connecting Quick Connect Cord

  • Maintenance

  • Trial Operation

  • Lighting Instructions

  • Shutdown Instructions

  • Manuel D'installation

  • Accessoires Inclus

  • Accessoires Optionnels

  • Schéma du Système

  • Avant L'installation

  • Dégagement Pour L'installation

  • Conduite de Gaz

  • Installation Électrique

  • Panneau de Commande

  • Test de Fonctionnement

  • Instructions D'allumage

  • Instructions D'arrêt

Advertisem*nt

Available languages

  • EN

Available languages

  • ENGLISH, page 1

Quick Links

  • 1 Maintenance
  • Download this manual

See also: Service Manual , Owner's Manual

Installation Manual

Canada

TANKLESS GAS WATER HEATER

Potential dangers from accidents during installation and use are divided into the following three

categories. Closely observe these warnings, they are critical to your safety.

DANGER

WARNING

CAUTION

WARNING:

If the information in this manual is not followed exactly, a fire or explosion may result

causing property damage, personal injury or death.

Prohibited

Requests to Installers

• In order to use the water heater safely, read this installation manual carefully, and follow the

installation instructions.

• Failures and damage caused by erroneous work or work not as instructed in this manual are not

covered by the warranty.

• Check that the installation was done properly in accordance with this Installation Manual upon completion.

• After completing installation, please either place this Installation Manual in a plastic pouch and

attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),

or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required

items on the warranty and to hand the warranty to the customer along with the Owner's Guide.

CERTIFIED

R

SAV8017-1

Department of Buildings

Rev. 10/08

N-0751M-DVC

DANGER indicates an imminently hazardous situation which,

if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation which,

if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation which,

if not avoided, may result in minor or moderate injury.

Disconnect

Power

CAUTION

Low NOx

Approved by

SCAQMD

Accepted For Use

City of New York

MEA 19-03-E

(Indoor Installation)

Ground

FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFAC-

TURED HOME APPLICATIONS.

Installation must conform with local codes, or in the absence of

local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54-

latest edition and/or CSA B149.1, Natural Gas and Propane In-

stallation Code (NSCNGPIC).

When applicable, installation must conform with the Manufactured Home

Construction and Safety Standard, Title 24 CFR, Part 3280 or the Cana-

dian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86.

Noritz America reserves the right to discontinue, or change at any

time, the designs and/or specifications of its products without notice.

NORITZ AMERICA

CORPORATION

Be sure to do

*SAV8017 C*

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

NORITZ N-0751M-DVC INSTALLATION MANUAL Pdf Download (3)

Related Manuals for Noritz N-0751M-DVC

  • Water Heater Noritz NR50-OD Service Manual

    (96 pages)

  • Water Heater Noritz N-0531S Field Manual

    Gas water heater (60 pages)

  • Water Heater Noritz NC199-DVC Owner's Manual

    Tankless (28 pages)

  • Water Heater Noritz N-0751M-DVC Installation Manual

    Tankless gas water heater (27 pages)

  • Water Heater Noritz N-0751M Owner's Manual

    Tankless gas water heater (26 pages)

  • Water Heater Noritz N-0931M Installation Manual

    Tankless gas water heater (34 pages)

  • Water Heater Noritz N-0751M Owner's Manual

    Tankless gas water heater (26 pages)

  • Water Heater Noritz N-0751M Installation Manual

    Tankless gas water heater (120 pages)

  • Water Heater Noritz NR98 Series Instructional Manual

    Fan replacement and cleaning procedure (4 pages)

  • Water Heater Noritz N-0751M-DV Installation Manual

    Tankless gas water heater (29 pages)

  • Water Heater Noritz N-0751M-OD Installation Manual

    Tankless gas water heater (27 pages)

  • Water Heater Noritz N-0751M-OD Owner's Manual

    Tankless gas water heater (26 pages)

  • Water Heater NORITZ N-0631S Installation Manual

    Tankless gas water heater (28 pages)

  • Water Heater Noritz NCC199-SV Owner's Manual

    Condensing tankless gas water heater (32 pages)

  • Water Heater Noritz N-063 Owner's Manual And Installation Manual

    (30 pages)

  • Water Heater Noritz N-084M Owner's Manual

    (67 pages)

Summary of Contents for Noritz N-0751M-DVC

  • Page 1 NORITZ AMERICA CORPORATION Canada TANKLESS GAS WATER HEATER N-0751M-DVC (Indoor Installation) Potential dangers from accidents during installation and use are divided into the following three categories. Closely observe these warnings, they are critical to your safety. DANGER indicates an imminently hazardous situation which, DANGER if not avoided, will result in death or serious injury.
  • Page 2: Included Accessories

    The following accessories are included with the unit. Included Accessories Check for any missing items before starting installation. Part Shape Part Shape Q’ty Q’ty Owner's Guide, Warranty, Tapping Screw Installation Manual each (this document) The accessories listed below are not Optional Accessories included with the units, but may be necessary for installation.
  • Page 3: Quick Connect Multi System Installation

    Quick Connect Multi System Installation • The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord. The Quick Connect Cord is 2m (6'). long. Install the units 50 - 450mm (2-18") apart from each other to ensure the cord will be able to reach between the units.
  • Page 4: Before Installation

    Check the Gas • Check that the rating plate indicates the correct type of gas. • Check that the gas supply line is sized for N-0751M-DVC 199,900 BTU 11,000 BTU 199,900 Btuh for this unit. 10.5"...
  • Page 5: Choosing Installation Site

    Choosing Installation Site * Locate the appliance in an area where leakage from the unit or connections will not result in damage to the area adjacent to the appliance or to the lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance.
  • Page 6 CAUTION • Avoid installation above gas ranges or stoves. • Avoid installation between the kitchen fan and stove. If oily fumes or a large amount of steam are present in the installation location, take measures to prevent the fumes and steam from Prohibited entering in the equipment.
  • Page 7: Installation Clearances

    Installation Clearances WARNING Before installing, check for the following: Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 –...
  • Page 8: Installation

    Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Vent Terminal Area Where Terminal is Not Permitted Air Supply Inlet Clearance Above grade, veranda, porch, deck,...
  • Page 9 • The weight of the device will be applied to the wall. If the strength of the wall is not suffi- cient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may be damaged and may become highly dangerous.
  • Page 10: Vent Pipe Installation

    Vent Pipe Installation WARNING CARBON MONOXIDE POISONING Follow all vent system requirements in accordance with relevant local or state regulation, or, in the absence of local or state code, in the U.S. to the National Fuel Gas Code ANSI Be sure to do Z233.1/NFPA 54 –...
  • Page 11 Maximum Vent Length Adjustment Connector The unit can be adjusted to accommodate longer vent runs; refer to the below table to find the maximum vent length based on the number of elbows. If the maximum vent length falls in the shaded area of the table, the airflow adjustment connector must be pulled out as illustrated to the right.
  • Page 12 • Exceeding the maximum vent length is danger- • Use only Noritz specified venting products. ous and may result in bad combustion. • Connect the vent pipe firmly so that it will prevent • Install the vent terminal so that all exhaust is di- exhaust gases from leaking.
  • Page 13 Vertical Vent Termination 1.5m (5') or more • Terminate at least 1.8m (6') from the combustion air intake of any appliance, and 0.9m (3') from Rain any other building opening, gas utility meter, service regulator etc. • Enclose exterior vent systems below the roof Air Intake Pipe line to limit condensation and protect against...
  • Page 14 Gas Piping Follow the instructions from the gas supplier. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ⁄ psig (3.5 kPa). The Appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ⁄...
  • Page 15 Gas Line Sizing for a Noritz Tankless Gas Water Heater Adapted from UPC 1997 Maximum Natur Natural Gas Delivery Capacity in Cubic Feet per Hour (0.60 Specific Gravity, 0.5" WC Pressure Drop) Length in Feet Pipe 3m (10') 6m (20') 9m (30') 12m (40') 15m (50')
  • Page 16: Water Piping

    Installation and service must be performed by a qualified plumber. In the Water Piping Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes. This appliance suitable for potable water and space heating applications.
  • Page 17 Supply water piping Hot water piping • Do not use PVC, iron, or any piping which has been • Do not use lead, PVC, iron or any piping which treated with chromates, boiler seal or other chemicals. has been treated with chromates, boiler seal or •...
  • Page 18: Water Treatment

    *Install Noritz Isolation Valves to allow for flushing. **Flushing is required if a water softener is not installed. Water Treatment System Shutoff Valve City Water Supply Cold to Water NORITZ Heater N-0751M-DVC Optional Sediment Filter Pressure Shutoff Valve Relief Valve Water Treatment Device...
  • Page 19: Plumbing Applications

    Plumbing Applications Recirculation System Notes: 1. Size the pump to provide a maximum of 7.5 L/min. (2 GPM) through the system at 3m (10 ft) of head plus piping losses. Hot Water Return Adjust the flow using a globe valve and verify the NORITZ Cold Water Supply flow rate with the maintenance monitors.
  • Page 20: Electrical Wiring

    Consult a qualified electrician Electrical Wiring for the electrical work. Do not connect electrical power to the unit until all electrical wiring has been completed. Disconnect Power This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
  • Page 21: Operation Panel

    To keep the water heater off, let the unit sit for 30 sec. to return to the original display. • The N-0751M-DVC can be programmed so that it will default to one of four temperatures if the remote controller is removed (80 C, 60 C, 55 C, 50 C (176 F, 140 F, 130 F, 122 F)). To change the default temperature, connect the temperature selection wire as shown in the above diagram.
  • Page 22: Pump Wiring

    * This feature is not available when using the Quick Con- Pump Wiring nect Multi System feature. Connecting the pump control wire 1. Leave enough slack so that the pump control wires will stay connected if the unit is removed from the Pump Control wall.
  • Page 23: Connecting Quick Connect Cord

    For Quick Connect Multi System Installation Connecting Quick Connect Cord usa a Quick Connect Cord (sold separately). Caution The wire coloring on the Quick Connect Cord will not be the same as the wire coloring of the connection plug inside the unit. 1.Red 1.Red 1.White...
  • Page 24: Maintenance

    Periodically check the following to ensure proper Maintenance operation of the water heater. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. • The burner flame must be checked periodically for a proper blue color and consistency. •...
  • Page 25: Lighting Instructions

    CAUTION Handling after trial operation • If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of the water out of the unit and the plumbing system to prevent the unit and system from freezing, and bleed the gas out of the gas line.
  • Page 26 Dimensions N-0751M-DVC < mm [inch] > 336mm [13.2"] 8-6 x 10mm [0.2" x 0.4"] OBLONG HOLE 6- 13mm [ 0.5"] 140mm [5.5"] 105mm [4.1"] 260mm [10.2"] 10 - 45mm 70mm [2.8"] 350mm [13.8"] [0.4" - 1.8"] 36mm [1.4"] 334mm [13.1"] 104mm [4.1"]...
  • Page 27: Manuel D'installation

    NORITZ AMERICA CORPORATION Canada CHAUFFE-EAU À GAZ SANS CUVE N-0751M-DVC (Installation intérieure) Les dangers potentiels provenant d’accidents pendant l’installation et l’utilisation sont classés dans les trois catégories suivantes. Observez bien ces avertissem*nts, ils sont indispensables à votre sécurité. DANGER indique une situation dangereuse imminente qui, si elle n'est DANGER pas évitée, entraînera des blessures graves ou mortelles.
  • Page 28: Accessoires Inclus

    Les accessoires suivants sont inclus avec l’unité. Accessoires inclus Vérifiez qu’il ne manque aucun élément avant de commencer l’installation. Pièce Forme Pièce Forme Qté Qté Guide de l’utilisateur, 1 de Garantie, Vis autotaraudeuse Manuel d’installation chaque (ce document) Les accessoires présentés ci-dessous ne Accessoires optionnels sont pas inclus avec l’unité, mais peuvent être nécessaires à...
  • Page 29: Schéma Du Système

    Installation du multisystème par raccordement rapide • Le multisystème à raccordement rapide permet d’installer deux unités ensemble en utilisant uniquement le cordon à raccordement rapide. Le cordon de raccordement rapide mesure 2m (6') de long. Installez les deux unités entre 50mm - 450mm (2-18") d’écart chacune pour garantir que le cordon puisse relier les deux unités.
  • Page 30: Avant L'installation

    à un amoncellement de neige ou contre les dégâts dus à une chute de neige du toit. Vérifiez le gaz • Vérifiez que la plaque signalétique indique le N-0751M-DVC type de gaz correct. 199,900 BTU 11,000 BTU •...
  • Page 31 Choix du site d’installation * Placez l’appareil dans un endroit où une fuite de l’unité ou des raccordements ne provoquera pas de dégâts à la zone adjacente à l’appareil ou aux étages inférieurs de la structure. Lorsque de tels emplacements ne peuvent pas être évités, il est recommandé de placer une bassine de rétention, proprement vidangée, sous l’appareil.
  • Page 32 ATTENTION • Evitez l’installation au-dessus de fourneau à gaz ou cuisinière. • Evitez l’installation entre le ventilateur et la cuisinière dans une cuisine. Si des fumées huileuses ou une grande quantité de vapeur sont présents sur l’emplacement d’installation, prenez Interdit des mesures pour empêcher les fumées et la vapeur de pénétrer dans l’équipement.
  • Page 33: Dégagement Pour L'installation

    Dégagement pour l'installation AVERTISsem*nT Avant l’installation, vérifiez les points suivants : Installez le chauffe-eau conformément aux codes du bâtiment et aux codes mécaniques applicables, ainsi qu'aux réglementations locales, de l'état ou nationales, ou en l'absence de réglementation locale ou de l'état, à la norme ANSI Z223.1/NFPA 54 - dernière édition du National Fuel Gas Code.
  • Page 34 Exigences de dégagement des bouches de l’évent par rapport aux ouvertures du bâtiment * Toutes les exigences de dégagement sont conformes à la norme ANSI Z21.10.3 et le National Fuel Gas Code, ANSI Z223.1 et au Canada NSCNGPIC. Zone où une bouche d’évent Bouche de l’évent est interdite...
  • Page 35 • Le poids de l’appareil sera appliqué sur le mur. Si la force du mur n’est pas suffisante, un renforcement doit être fait pour empêcher un transfert de la vibration. • Ne laissez pas tomber ni n’usez de force inutile sur l’appareil lors de l’installation. Les pièces internes pourraient être endommagées et devenir très dangereuses.
  • Page 36 Installation du tuyau d’évent AVERTISsem*nT EMPOISONNEMENT AU MONOXYDE DE CARBONE Respectez toutes les exigences du système de ventilation conformément aux réglementations locales ou de l’état ou en l’absence de réglementation locale ou de l’état, aux Etats-Unis à la norme ANSI Z233.1/NFPA 54 Veillez à...
  • Page 37 Longueur max. du conduit d’évacuation et connecteur de réglage Il est possible de régler cette unité pour recevoir des canalisations plus longues ; reportez-vous au tableau ci-dessous pour trouver la longueur de conduit maximum d’après le nombre de coudes. Si la longueur de conduit maximum tombe dans la zone grisée du tableau, le connecteur du réglage du débit d’air doit être retiré...
  • Page 38 • Dépasser la longueur maximale de la conduite • N’utilisez que les produits de ventilation spécifiés d’évacuation est dangereux et peut entraîner par Noritz. une mauvaise combustion. • Connectez solidement le tuyau d’évent afin • Installez la bouche de l’évent de sorte que tout le d’empêcher la fuite des gaz d’échappement.
  • Page 39 Bouche de l’évent vertical Au moins 1.5m (5') • Terminez au moins 1.8m (6') de l’entrée Bouchon d’air comburant d’un appareil et 0.9m (3') contre d’une ouverture d’un bâtiment, compteur à la pluie gaz, régulateur de gaz, etc. • Enfermez les systèmes d’évent extérieur Air aspiré...
  • Page 40: Conduite De Gaz

    Conduite de gaz Suivez les instructions du fournisseur de gaz. L’appareil et son robinet d’arrêt du gaz doivent être débranchés du système de conduites de distribution du gaz durant tout essai de pression à des pressions supérieures à ⁄ psi (3.5 kPa). L’appareil doit être isolé...
  • Page 41 Calibrage de la canalisation de gaz pour un Noritz Chauffe-eau à Gaz Sans Cuve à Condensation Adapté de UC1997 Capacité maximum de distribution du gaz naturel en pied cubique par heures (Gravité spécifique 0.60, Perte de pression 0.5" WC) Calibre Longueur en pieds 3m (10') 6m (20')
  • Page 42 L'installation et l'entretien doivent être assurés par un plombier qualifié. Dans l'état du Commonwealth of Massachusetts, cet appareil doit être Conduite d’eau installé par un plombier ou un monteur d'installation au gaz agréés conformément aux sections 2.00 et 5.00 du Massachusetts Plumbing and Fuel Gas Code 248 CMR.
  • Page 43 Conduite de distribution d’eau Conduite d’eau chaude • N'utilisez pas de PVC, acier ou de tuyaux traités au • N'utilisez pas de plomb, PVC, acier ou de tuyaux traités au chromate, scellement par plomb pour chaudière ou chromate, scellement par plomb pour chaudière ou autres autres produits chimiques.
  • Page 44 ** La purge est nécessaire si un adoucisseur d ’ eau n ’ est pas installé. Système de traitement de l’eau Valve d’arrêt Alimentation en Froid vers NORITZ eau urbaine chauffe-eau N-0751M-DVC Filtre à sédiments en option Soupape de sûreté Valve d’arrêt de la pression Appareil de traitement de l’eau...
  • Page 45 Plomberie Système de recirculation Remarques : 1. Calibrez la pompe pour fournir un maximum de 7.5 L/min (2 GPM) à travers le système à 3m 10 ft) de hauteur de refoulement plus les pertes de tuyauterie. Ajustez le débit à l’aide d’un robinet à soupape et Retour d’eau chaude Alimentation en vérifiez la vitesse d’écoulement avec les...
  • Page 46: Installation Électrique

    Adressez-vous à un électricien Installation électrique qualifié pour l’installation électrique. Ne branchez pas le courant à l’unité avant que toute l’installation électrique soit achevée. Couper l’alimentation électrique Cet appareil doit être relié à la terre électriquement en conformité avec les réglementations locales ou en l’absence de réglementation locale, avec la norme ANSI 70 54 du National Fuel Gas Code.
  • Page 47: Panneau De Commande

    • Le N-0751M-DVC peut être programmé de sorte qu'il revienne au réglage par défaut d'une des quatre températures si la télécommande est déplacée (80 C, 60 C, 55 C, 50 C (176 F, 140 F, 130 F, 122 F)). Pour modifier la température par défaut, branchez le câble de sélection de température comme illustré...
  • Page 48 * Cette fonction n’est pas disponible lorsque vous utilisez la fonction Câblage de la pompe multisystème à raccordement rapide. Raccordement du câble de commande de la pompe 1. Laissez suffisamment de jeu de sorte que les câbles de commande de la pompe restent Etiquette du câble branchés si l’unité...
  • Page 49 Pour l’installation du multisystème par raccordement rapide, Branchement du cordon de raccordement rapide utilisez un cordon de raccordement rapide (vendu séparément). Attention La couleur des câbles sur le cordon de raccordement rapide sera différente de celle des câbles de la fiche de jonction dans l’unité. 1.Rouge 1.Rouge 1.Blanc...
  • Page 50: Test De Fonctionnement

    Vérifiez régulièrement les points suivants pour Maintenance garantir un bon fonctionnement du chauffe-eau. • Le système de ventilation doit être examiné régulièrement par un technicien de service qualifié pour vérifier les fuites ou la corrosion. • La flamme du brûleur doit être vérifiée régulièrement pour une couleur bleue et une consistance adéquates. •...
  • Page 51: Instructions D'allumage

    ATTENTION Manipulation après le test de fonctionnement • Si l’unité ne sera pas utilisée immédiatement, fermez tous les robinets d’arrêt du gaz et de l’eau, vidangez toute l’eau de l’unité et du système de plomberie pour prévenir le gel de l’unité et du système et purgez la canalisation de gaz.
  • Page 52 Dimensions N-0751M-DVC < mm [inch] > 336mm [13.2"] Trou oblong 8-6 x 10mm [0.2" x 0.4"] 6- 13mm [ 0.5"] 140mm [5.5"] 105mm [4.1"] 260mm [10.2"] 10 - 45mm 70mm [2.8"] 350mm [13.8"] [0.4" - 1.8"] 36mm [1.4"] 334mm [13.1"] 104mm [4.1"]...
NORITZ N-0751M-DVC INSTALLATION MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Sen. Emmett Berge

Last Updated:

Views: 5855

Rating: 5 / 5 (80 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Sen. Emmett Berge

Birthday: 1993-06-17

Address: 787 Elvis Divide, Port Brice, OH 24507-6802

Phone: +9779049645255

Job: Senior Healthcare Specialist

Hobby: Cycling, Model building, Kitesurfing, Origami, Lapidary, Dance, Basketball

Introduction: My name is Sen. Emmett Berge, I am a funny, vast, charming, courageous, enthusiastic, jolly, famous person who loves writing and wants to share my knowledge and understanding with you.